Linearized plasmid standard
Convert a plasmid stock before preparing standards.
Convert DNA concentration to copies/µL and plan your qPCR standards.
2.9 × 10⁸ copies per ng · 12.0 nM · MW 2.09 × 10⁶ g/mol
Dilute 1:1,441 for 1.0 × 10⁷ copies in 2 µL
617.96 g/mol/bp + 36.04 convention: 7.7 × 10⁹ copies/µL.
Choose a starting point and adapt it to your experiment.
Convert a plasmid stock before preparing standards.
Calculate copies in a synthetic DNA fragment.
Plan a dilution series from an amplicon.
Estimate haploid genome copies in a DNA sample.
Prepare standards from a bacterial genome.
Estimate a dilution for a digital PCR reaction.
Convert an RNA standard from mass concentration.
Convert a molar oligonucleotide concentration.
Calculate unknown copies from measured Cq values.
Report copy number relative to input DNA.
Prepare a standard series in four steps.
Select the template and enter its length or sequence.
Convert the stock concentration to copies per microlitre.
Set the highest standard and number of points.
Copy or print the dilution instructions.
Convert mass or molar concentration to molecule count.
For 3,165 bp at 25 ng/µL, the 660 convention gives 7.2 × 10⁹ copies/µL.
| Mass convention | Copies per µL |
|---|---|
| 660 g/mol/bp | 7.2 × 10⁹ |
| 617.96 g/mol/bp + 36.04 g/mol | 7.7 × 10⁹ |
| Sequence-specific molecular weight | Sequence required |
References: Thermo Fisher: Standard Curves · QIAGEN: dsDNA Mass Moles Converter
Use measured Cq values to estimate unknown copy numbers.
Slope, efficiency, and R² describe standard curve quality. Use the Delta Delta Ct Calculator for efficiency-corrected relative expression.
References: MIQE 2009 · Hou et al. 2010
Divide the mass in grams by molecular weight, then multiply by Avogadro’s constant. For dsDNA, molecular weight is commonly estimated from length multiplied by 660 g/mol per base pair.
Both are approximations. Use one convention consistently and report it; for a sequence-specific molecular weight, paste the sequence.
A fluorometric assay is more specific for dsDNA. Absorbance can include RNA and free nucleotides; convert an A260 reading to ng/µL before using this tool. To calculate concentration from absorbance, use the Beer–Lambert Law Calculator.
Prepare a suitable pre-dilution and then make each tenfold step with volumes your pipette can deliver. Allow enough volume for every replicate. Use the Serial Dilution Calculator for general dilution planning.
Use an appropriate carrier or low-binding tubes and prepare aliquots to avoid repeated freezing and thawing.
Fit Cq against log₁₀ copies for the standards, then invert the fitted line. Interpret unknowns within the tested standard range. Slope, efficiency, and R² describe standard curve quality. Use the Delta Delta Ct Calculator for efficiency-corrected relative expression.
About 294 haploid copies for a 3.1 Gb genome at 660 g/mol per base pair, equivalent to about 147 diploid cells. Multi-copy targets require their genomic copy number to be considered.
No. Copies in a solution count molecules; copies per cell require quantification of a plasmid target and a single-copy chromosomal target, followed by their ratio.
Yes, you can plan sample dilutions. Digital PCR software estimates concentration from partition counts without requiring a standard curve.
Turn your template concentration into a practical series.
Calculate copy number